TORRI
ModelAURA 15 K-GCAURA 25 K-GC
Inverter Trifase Commerciale
AURA

Three-phase inverter for medium-sized commercial systems.

Inverter Trifase Commerciale
Efficiency
Maximum efficiency98.4%
Weighted efficiency (Euro)98.0%
PV input technical data
Maximum input voltage1100V
Maximum DC input power22500W37500W
Nominal input voltage620V
Maximum input current2*30A
Maximum current per MPPT2*40A
Nominal start-up voltage180V
MPPT DC voltage range160V - 1000V
Max. number of strings per MPPT4 (2/2)
No. of independent MPPTs2
AC output technical data
AC nominal active power15000W25000W
Maximum AC apparent power16500VA27500VA
Maximum AC active power (PF=1)16500W27500W
Max. AC output current3*25.3A3*39.8A
AC nominal voltage380V / 400V / 415V, 3W+N+PE
AC voltage range260V-510V (adjustable according to local grid standards)
Nominal grid frequency50Hz / 60Hz
Grid frequency range45Hz-55Hz / 55Hz-65Hz (In accordance with local grid standards)
Total harmonic distortion<3% (Nominal power)
Power factor> 0.99 Rated power (Adjustable 0.8 LD - 0.8 LG)
Grid feed-in limitation*Programmable
Protection
DC disconnectorSupported
Anti-islanding protectionSupported
AC overvoltage protectionSupported
AC short-circuit protectionSupported
DC reverse connectionSupported
Surge arresterCA Tipo III (Tipo II opzionale) / CC Tipo III (Tipo II opzionale)
Insulation detectionSupported
Leakage current protectionSupported
General data
TypeTransformerless
Environmental protection ratingIP66
Night consumption<1W
CoolingForced convection by fans
Operating temperature range-25° / +60°
Relative humidity range0-100%
Maximum altitude4000m
Noise<45dB
Dimensions (W*H*D)398mm*460mm*190mm
Weight20Kg
HMI & COM
DisplayWireless & APP+LED, LCD (Optional)
Interface communicationRS485, Optional: WiFi / GPRS / 4G / LAN
Product certifications
Grid connection standardVDE-AR-N 4105, EN 50549-1, CEI 0-21, UNE 206006/206007-1, RD 1699/661&413, IEC 61727/62116, AS4777.2
SafetyIEC62109-1, IEC62109-2
Warranty10 YEARS
Company certifications
ISO 9001:2015 QualityKIWA
ISO 14001:2015 EnvironmentKIWA
ISO 45001:2018 SafetyKIWA
Factory Inspection Attestation Photovoltaic (PV) PanelsKIWA

* The output voltage and frequency range may vary depending on local regulations. Specifications are subject to change without notice.

* The power delivered in backup depends on the number and type of batteries as well as on the system state (Temperature, Remaining capacity).

Technical specifications are subject to continuous updates and may change at any time without notice.

Please verify warranty conditions and validity directly with the company at the time of purchase.

TORRI — Beyond Ordinary Solar
Products
Inverter Trifase Commerciale
Inverters · AURA

Three-Phase Commercial Inverter

Three-phase inverter for medium-sized commercial systems.

Request infoDownload
01 · Description

The product

Three-phase inverter for medium-sized commercial systems.

Designed and manufactured in Italy according to TORRI's product culture: build quality, industrial robustness and long-term durability.

02 · Technologies used

Technologies used

03 · Datasheet

Complete datasheet

ModelAURA 15 K-GCAURA 25 K-GC
Efficiency
Maximum efficiency98.4%
Weighted efficiency (Euro)98.0%
PV input technical data
Maximum input voltage1100V
Maximum DC input power22500W37500W
Nominal input voltage620V
Maximum input current2*30A
Maximum current per MPPT2*40A
Nominal start-up voltage180V
MPPT DC voltage range160V - 1000V
Max. number of strings per MPPT4 (2/2)
No. of independent MPPTs2
AC output technical data
AC nominal active power15000W25000W
Maximum AC apparent power16500VA27500VA
Maximum AC active power (PF=1)16500W27500W
Max. AC output current3*25.3A3*39.8A
AC nominal voltage380V / 400V / 415V, 3W+N+PE
AC voltage range260V-510V (adjustable according to local grid standards)
Nominal grid frequency50Hz / 60Hz
Grid frequency range45Hz-55Hz / 55Hz-65Hz (In accordance with local grid standards)
Total harmonic distortion<3% (Nominal power)
Power factor> 0.99 Rated power (Adjustable 0.8 LD - 0.8 LG)
Grid feed-in limitation*Programmable
Protection
DC disconnectorSupported
Anti-islanding protectionSupported
AC overvoltage protectionSupported
AC short-circuit protectionSupported
DC reverse connectionSupported
Surge arresterCA Tipo III (Tipo II opzionale) / CC Tipo III (Tipo II opzionale)
Insulation detectionSupported
Leakage current protectionSupported
General data
TypeTransformerless
Environmental protection ratingIP66
Night consumption<1W
CoolingForced convection by fans
Operating temperature range-25° / +60°
Relative humidity range0-100%
Maximum altitude4000m
Noise<45dB
Dimensions (W*H*D)398mm*460mm*190mm
Weight20Kg
HMI & COM
DisplayWireless & APP+LED, LCD (Optional)
Interface communicationRS485, Optional: WiFi / GPRS / 4G / LAN
Product certifications
Grid connection standardVDE-AR-N 4105, EN 50549-1, CEI 0-21, UNE 206006/206007-1, RD 1699/661&413, IEC 61727/62116, AS4777.2
SafetyIEC62109-1, IEC62109-2
Warranty10 YEARS
Company certifications
ISO 9001:2015 QualityKIWA
ISO 14001:2015 EnvironmentKIWA
ISO 45001:2018 SafetyKIWA
Factory Inspection Attestation Photovoltaic (PV) PanelsKIWA

* The output voltage and frequency range may vary depending on local regulations. Specifications are subject to change without notice.

* The power delivered in backup depends on the number and type of batteries as well as on the system state (Temperature, Remaining capacity).

Technical specifications are subject to continuous updates and may change at any time without notice.

Please verify warranty conditions and validity directly with the company at the time of purchase.

04 · Download

Documentation

Datasheet

PDF · Three-Phase Commercial Inverter

Product documents

Browse the list. Downloads are reserved to the Customer Area.

Manuale d’uso

Inverter · PDF · 12.4 MB

Log in to download

Guida Rapida

Inverter · PDF · 2.9 MB

Log in to download

Garanzia

Inverter · PDF · 1.3 MB

Log in to download

CEI 0-21

Inverter · PDF · 278 KB

Log in to download

DI.CO – CEI 0-21

Inverter · PDF · 511 KB

Log in to download

CEI 0-16

Inverter · PDF · 275 KB

Log in to download

DI.CO – CEI 0-16

Inverter · PDF · 508 KB

Log in to download

Guida collegamento WI-FI

Manuale di installazione · Inverter · PDF · 528 KB

Log in to download

All documents in the Customer Area

Log in to the Customer Area to download all product documentation: datasheets, manuals, certifications and warranties.

Customer Area
App + web portal

TORRI Monitoring

Your system always under control, from your smartphone or computer.

  • Real-time production, consumption and energy flows
  • Daily, monthly and yearly energy analysis
  • Battery status and grid exchange
  • Remote settings for inverter, grid and battery

No system yet? Open the app and tap “Demo” to explore it.

TORRI Monitoring appTORRI Monitoring appTORRI Monitoring appTORRI Monitoring app
TORRI Monitoring app
Information

Request information about Three-Phase Commercial Inverter

Would you like to know more about this product, get a quote or talk to a technician? Fill in the form: we'll get back to you with all the details.

Request information about · Three-Phase Commercial Inverter

By submitting, you accept the processing of data according to the Privacy Policy.