| Model | AURA 50 K-GC | AURA 100 K-GC |
60–100 kW three-phase industrial inverter for large systems.

| Maximum efficiency | 98.5% | |
| Weighted efficiency (Euro) | 97.9% | 98.0% |
| Maximum input voltage | 1100V | |
| Maximum DC input power | 75000W | 150000W |
| Nominal input voltage | 620V | |
| Maximum input current | 136A (32A/32A/32A/40A) | 3*40A + 5*32A |
| Maximum current per MPPT | 185A (45A/45A/45A/50A) | 3*50A + 5*45A |
| Nominal start-up voltage | 200V | 250V / 200V |
| MPPT DC voltage range | 180V-1000V | 200V-1000V |
| Max. number of strings per MPPT | 8 (2/2/2/2) | 16 (8*2) |
| No. of independent MPPTs | 4 | 8 |
| AC nominal active power | 50000W | 100000W |
| Maximum AC apparent power | 55600VA | 110000VA |
| Maximum AC active power (PF=1) | 55600W | 110000W |
| Max. AC output current | 3*84.3 A | 3*168.8 A |
| AC nominal voltage | 380V / 400V / 415V, 3W+N+PE | |
| AC voltage range | 277V-520V (adjustable according to local grid standards) | |
| Nominal grid frequency | 50Hz / 60Hz | |
| Grid frequency range | 45Hz-55Hz / 55Hz-65Hz (In accordance with local grid standards) | |
| Total harmonic distortion | <3% (Nominal power) | |
| Power factor | > 0.99 Rated power (Adjustable 0.8 LD - 0.8 LG) | |
| Grid feed-in limitation* | Programmable | |
| DC disconnector | Supported | |
| Anti-islanding protection | Supported | |
| AC overvoltage protection | Supported | |
| AC short-circuit protection | Supported | |
| DC reverse connection | Supported | |
| Surge arrester | DC Tipo II / AC Tipo II | |
| Insulation detection | Supported | |
| Leakage current protection | Supported | |
| Type | Transformerless | |
| Environmental protection rating | IP65 | |
| Night consumption | <1W | <10W |
| Cooling | Forced convection by fans | |
| Operating temperature range | -25° / +60° | |
| Relative humidity range | 0-100% | |
| Maximum altitude | 4000m | |
| Noise | <65dB | <75dB |
| Dimensions (W*H*D) | 635mm*530mm*224mm | 850mm*670mm*356mm |
| Weight | 42Kg | 92Kg |
| Display | Wireless & APP+LED | |
| Interface communication | RS485, Optional: WiFi / GPRS / 4G / LAN | |
| Grid connection standard | VDE-AR-N 4105, EN 50549-1, CEI 0-21/16, G99, UNE 206006/206007-1, UNE 217001, IEC 61727/62116, VDE 0126 | |
| Safety | IEC62109-1, IEC62109-2 | |
| Warranty | 10 YEARS | |
| ISO 9001:2015 Quality | KIWA | |
| ISO 14001:2015 Environment | KIWA | |
| ISO 45001:2018 Safety | KIWA | |
| Factory Inspection Attestation Photovoltaic (PV) Panels | KIWA | |
* The output voltage and frequency range may vary depending on local regulations. Specifications are subject to change without notice.
* The power delivered in backup depends on the number and type of batteries as well as on the system state (Temperature, Remaining capacity).
Technical specifications are subject to continuous updates and may change at any time without notice.
Please verify warranty conditions and validity directly with the company at the time of purchase.

60–100 kW three-phase industrial inverter for large systems.
60–100 kW three-phase industrial inverter for large systems.
Designed and manufactured in Italy according to TORRI's product culture: build quality, industrial robustness and long-term durability.
| Model | AURA 50 K-GC | AURA 100 K-GC |
| Maximum efficiency | 98.5% | |
| Weighted efficiency (Euro) | 97.9% | 98.0% |
| Maximum input voltage | 1100V | |
| Maximum DC input power | 75000W | 150000W |
| Nominal input voltage | 620V | |
| Maximum input current | 136A (32A/32A/32A/40A) | 3*40A + 5*32A |
| Maximum current per MPPT | 185A (45A/45A/45A/50A) | 3*50A + 5*45A |
| Nominal start-up voltage | 200V | 250V / 200V |
| MPPT DC voltage range | 180V-1000V | 200V-1000V |
| Max. number of strings per MPPT | 8 (2/2/2/2) | 16 (8*2) |
| No. of independent MPPTs | 4 | 8 |
| AC nominal active power | 50000W | 100000W |
| Maximum AC apparent power | 55600VA | 110000VA |
| Maximum AC active power (PF=1) | 55600W | 110000W |
| Max. AC output current | 3*84.3 A | 3*168.8 A |
| AC nominal voltage | 380V / 400V / 415V, 3W+N+PE | |
| AC voltage range | 277V-520V (adjustable according to local grid standards) | |
| Nominal grid frequency | 50Hz / 60Hz | |
| Grid frequency range | 45Hz-55Hz / 55Hz-65Hz (In accordance with local grid standards) | |
| Total harmonic distortion | <3% (Nominal power) | |
| Power factor | > 0.99 Rated power (Adjustable 0.8 LD - 0.8 LG) | |
| Grid feed-in limitation* | Programmable | |
| DC disconnector | Supported | |
| Anti-islanding protection | Supported | |
| AC overvoltage protection | Supported | |
| AC short-circuit protection | Supported | |
| DC reverse connection | Supported | |
| Surge arrester | DC Tipo II / AC Tipo II | |
| Insulation detection | Supported | |
| Leakage current protection | Supported | |
| Type | Transformerless | |
| Environmental protection rating | IP65 | |
| Night consumption | <1W | <10W |
| Cooling | Forced convection by fans | |
| Operating temperature range | -25° / +60° | |
| Relative humidity range | 0-100% | |
| Maximum altitude | 4000m | |
| Noise | <65dB | <75dB |
| Dimensions (W*H*D) | 635mm*530mm*224mm | 850mm*670mm*356mm |
| Weight | 42Kg | 92Kg |
| Display | Wireless & APP+LED | |
| Interface communication | RS485, Optional: WiFi / GPRS / 4G / LAN | |
| Grid connection standard | VDE-AR-N 4105, EN 50549-1, CEI 0-21/16, G99, UNE 206006/206007-1, UNE 217001, IEC 61727/62116, VDE 0126 | |
| Safety | IEC62109-1, IEC62109-2 | |
| Warranty | 10 YEARS | |
| ISO 9001:2015 Quality | KIWA | |
| ISO 14001:2015 Environment | KIWA | |
| ISO 45001:2018 Safety | KIWA | |
| Factory Inspection Attestation Photovoltaic (PV) Panels | KIWA | |
* The output voltage and frequency range may vary depending on local regulations. Specifications are subject to change without notice.
* The power delivered in backup depends on the number and type of batteries as well as on the system state (Temperature, Remaining capacity).
Technical specifications are subject to continuous updates and may change at any time without notice.
Please verify warranty conditions and validity directly with the company at the time of purchase.
Datasheet
PDF · Three-Phase Industrial Inverter
Browse the list. Downloads are reserved to the Customer Area.
Guida Rapida 60K
Inverter · PDF · 7.7 MB
Guida Rapida 100K
Inverter · PDF · 3.3 MB
Manuale d’uso
Inverter · PDF · 6.2 MB
Garanzia
Inverter · PDF · 1.3 MB
DI.CO AURA 100K-GC – CEI 0-21
Inverter · PDF · 505 KB
DI.CO AURA 100K-GC – CEI 0-16
Inverter · PDF · 506 KB
Certificazione CEI 0-21 AURA 100K-GC
Inverter · PDF · 3.7 MB
Certificazione CEI 0-16 AURA 100K-GC
Inverter · PDF · 3.7 MB
DI.CO AURA 60K-GC – CEI 0-21
Inverter · PDF · 505 KB
Certificazione CEI 0-21 AURA 60K-GC
Inverter · PDF · 582 KB
DI.CO AURA 60K-GC – CEI 0-16
Inverter · PDF · 511 KB
Certificazione CEI 0-16 AURA 60K-GC
Inverter · PDF · 582 KB
Guida collegamento WI-FI
Manuale di installazione · Inverter · PDF · 528 KB
All documents in the Customer Area
Log in to the Customer Area to download all product documentation: datasheets, manuals, certifications and warranties.
Your system always under control, from your smartphone or computer.
No system yet? Open the app and tap “Demo” to explore it.





Would you like to know more about this product, get a quote or talk to a technician? Fill in the form: we'll get back to you with all the details.