TORRI
ModelAURA 50 K-GCAURA 100 K-GC
Inverter Trifase Industriale
AURA

60–100 kW three-phase industrial inverter for large systems.

Inverter Trifase Industriale
Efficiency
Maximum efficiency98.5%
Weighted efficiency (Euro)97.9%98.0%
PV input technical data
Maximum input voltage1100V
Maximum DC input power75000W150000W
Nominal input voltage620V
Maximum input current136A (32A/32A/32A/40A)3*40A + 5*32A
Maximum current per MPPT185A (45A/45A/45A/50A)3*50A + 5*45A
Nominal start-up voltage200V250V / 200V
MPPT DC voltage range180V-1000V200V-1000V
Max. number of strings per MPPT8 (2/2/2/2)16 (8*2)
No. of independent MPPTs48
AC output technical data
AC nominal active power50000W100000W
Maximum AC apparent power55600VA110000VA
Maximum AC active power (PF=1)55600W110000W
Max. AC output current3*84.3 A3*168.8 A
AC nominal voltage380V / 400V / 415V, 3W+N+PE
AC voltage range277V-520V (adjustable according to local grid standards)
Nominal grid frequency50Hz / 60Hz
Grid frequency range45Hz-55Hz / 55Hz-65Hz (In accordance with local grid standards)
Total harmonic distortion<3% (Nominal power)
Power factor> 0.99 Rated power (Adjustable 0.8 LD - 0.8 LG)
Grid feed-in limitation*Programmable
Protection
DC disconnectorSupported
Anti-islanding protectionSupported
AC overvoltage protectionSupported
AC short-circuit protectionSupported
DC reverse connectionSupported
Surge arresterDC Tipo II / AC Tipo II
Insulation detectionSupported
Leakage current protectionSupported
General data
TypeTransformerless
Environmental protection ratingIP65
Night consumption<1W<10W
CoolingForced convection by fans
Operating temperature range-25° / +60°
Relative humidity range0-100%
Maximum altitude4000m
Noise<65dB<75dB
Dimensions (W*H*D)635mm*530mm*224mm850mm*670mm*356mm
Weight42Kg92Kg
HMI & COM
DisplayWireless & APP+LED
Interface communicationRS485, Optional: WiFi / GPRS / 4G / LAN
Product certifications
Grid connection standardVDE-AR-N 4105, EN 50549-1, CEI 0-21/16, G99, UNE 206006/206007-1, UNE 217001, IEC 61727/62116, VDE 0126
SafetyIEC62109-1, IEC62109-2
Warranty10 YEARS
Company certifications
ISO 9001:2015 QualityKIWA
ISO 14001:2015 EnvironmentKIWA
ISO 45001:2018 SafetyKIWA
Factory Inspection Attestation Photovoltaic (PV) PanelsKIWA

* The output voltage and frequency range may vary depending on local regulations. Specifications are subject to change without notice.

* The power delivered in backup depends on the number and type of batteries as well as on the system state (Temperature, Remaining capacity).

Technical specifications are subject to continuous updates and may change at any time without notice.

Please verify warranty conditions and validity directly with the company at the time of purchase.

TORRI — Beyond Ordinary Solar
Products
Inverter Trifase Industriale
Inverters · AURA

Inverter Trifase Industriale

60–100 kW three-phase industrial inverter for large systems.

Request info
01 · Description

The product

60–100 kW three-phase industrial inverter for large systems.

Designed and manufactured in Italy according to TORRI's product culture: build quality, industrial robustness and long-term durability.

02 · Technologies used

Technologies used

03 · Datasheet

Complete datasheet

ModelAURA 50 K-GCAURA 100 K-GC
Efficiency
Maximum efficiency98.5%
Weighted efficiency (Euro)97.9%98.0%
PV input technical data
Maximum input voltage1100V
Maximum DC input power75000W150000W
Nominal input voltage620V
Maximum input current136A (32A/32A/32A/40A)3*40A + 5*32A
Maximum current per MPPT185A (45A/45A/45A/50A)3*50A + 5*45A
Nominal start-up voltage200V250V / 200V
MPPT DC voltage range180V-1000V200V-1000V
Max. number of strings per MPPT8 (2/2/2/2)16 (8*2)
No. of independent MPPTs48
AC output technical data
AC nominal active power50000W100000W
Maximum AC apparent power55600VA110000VA
Maximum AC active power (PF=1)55600W110000W
Max. AC output current3*84.3 A3*168.8 A
AC nominal voltage380V / 400V / 415V, 3W+N+PE
AC voltage range277V-520V (adjustable according to local grid standards)
Nominal grid frequency50Hz / 60Hz
Grid frequency range45Hz-55Hz / 55Hz-65Hz (In accordance with local grid standards)
Total harmonic distortion<3% (Nominal power)
Power factor> 0.99 Rated power (Adjustable 0.8 LD - 0.8 LG)
Grid feed-in limitation*Programmable
Protection
DC disconnectorSupported
Anti-islanding protectionSupported
AC overvoltage protectionSupported
AC short-circuit protectionSupported
DC reverse connectionSupported
Surge arresterDC Tipo II / AC Tipo II
Insulation detectionSupported
Leakage current protectionSupported
General data
TypeTransformerless
Environmental protection ratingIP65
Night consumption<1W<10W
CoolingForced convection by fans
Operating temperature range-25° / +60°
Relative humidity range0-100%
Maximum altitude4000m
Noise<65dB<75dB
Dimensions (W*H*D)635mm*530mm*224mm850mm*670mm*356mm
Weight42Kg92Kg
HMI & COM
DisplayWireless & APP+LED
Interface communicationRS485, Optional: WiFi / GPRS / 4G / LAN
Product certifications
Grid connection standardVDE-AR-N 4105, EN 50549-1, CEI 0-21/16, G99, UNE 206006/206007-1, UNE 217001, IEC 61727/62116, VDE 0126
SafetyIEC62109-1, IEC62109-2
Warranty10 YEARS
Company certifications
ISO 9001:2015 QualityKIWA
ISO 14001:2015 EnvironmentKIWA
ISO 45001:2018 SafetyKIWA
Factory Inspection Attestation Photovoltaic (PV) PanelsKIWA

* The output voltage and frequency range may vary depending on local regulations. Specifications are subject to change without notice.

* The power delivered in backup depends on the number and type of batteries as well as on the system state (Temperature, Remaining capacity).

Technical specifications are subject to continuous updates and may change at any time without notice.

Please verify warranty conditions and validity directly with the company at the time of purchase.

Information

Request information about Inverter Trifase Industriale

Would you like to know more about this product, get a quote or talk to a technician? Fill in the form: we'll get back to you with all the details.

Request information about · Inverter Trifase Industriale

By submitting, you accept the processing of data according to the Privacy Policy.